Power cable aluminum armored. Power cable APVBbShp. Technical characteristics, decoding and design

Antipyretics for children are prescribed by a pediatrician. But there are situations of emergency care for fever, when the child needs to give the medicine immediately. Then the parents take responsibility and apply antipyretic drugs. What is allowed to give to infants? How can you bring down the temperature in older children? Which medications are the safest?

Cable АПвБбШп is the armored power cable which veins are made of aluminum. The insulating material is represented by crosslinked polyethylene (PES). In 2011, GOST-R 53769-2010 entered into force, during which the designation of the cable changed to APVBshp. Wherein design features  and the parameters of the conductor are preserved.

The cable price APVBbShp is determined by the number of cores and the cross-sectional area per 1 meter of conductor. When there is a need for conductors of non-standard sizes, manufacturers produce products to order. In our company you can buy a cable APVBbShp at affordable prices. At purchase the certificate of cable АПвБбШп and other necessary documentation are given.

Power cable  АПвБбШп during operation has shown, that is strong enough and durable electrotechnical product. Despite the acceptable and low price, can work in difficult conditions.

Explanation

The decoding of the APVBbShp cable includes the following letter symbols:

  • A - current-carrying vein is made of aluminum;
  • Pv - SPE insulation;
  • Бб - has armor in the form of the zinced tapes from steel;
  • Шп - a protective cover from СПЭ-isolation:
  • (d) - the requirements of MKS "Mosenergo" were met;

Features & Benefits

Cable APVBBShp is not limited by any requirements of working environment conditions. Installation can be carried out at any angle of inclination of the gasket: horizontal, inclined and vertical cable routes. According to the manufacturer's instructions, the conductor operation can take place at a low temperature in the working room.

Application

Power cable АПвБбШп serves as a feeding element for power supply of fixed stationary units. The working nominal voltage is 1/1000 kV / V of the industrial frequency (50 Hz).

The climatic zones are represented by temperate and cold climates. Operation can be carried out in coastal and river areas, on land. The height above sea level is up to 4300 m.

Conditions of installation in the ground in the absence of the operating tension forces during operation: the level of corrosive activity of the soil is low, medium and high; wandering currents are not normalized.

Elevated soil moisture does not affect the operating conditions.

Installation in water is permissible.

The installation of the conductor may be carried out at any angles of inclination of the track, on horizontal, inclined and vertical surfaces. Allowable overheating of live conductor in an emergency situation up to t = + 130 ° C. The duration of the accident is not allowed for more than 6 hours.

Wire composition


  1. Current-carrying aluminum wire of class Ι or ΙΙ according to GOST 22483-77.
  2. The insulating material is made of EIT.
  3. Polyethylene inner sheath.
  4. The reservation is made in the form of two galvanized steel tapes.
  5. The material of the protective hose is cross-linked polyethylene.

The maximum protection of the conductor is provided by means of an outer shell, made in the form of galvanized strip strips made of steel. Tape strips overlap with each other, creating a reliable protection. This cable АПвБбШп, according to its normative and technical parameters, allows to lay in the ground at different levels of processes of corrosive activity, the presence of fault currents is not standardized. It is allowed to work in rooms with a high level of humidity and water. However, the cable should not be subjected to mechanical strains.


Specifications

Basic technical characteristics APBBbShp  are presented below:

  • The rated voltage is 1/1000 kV / V;
  • The limit of the permissible operating temperature is t = ± 50 ° C;
  • The relative humidity level at t = + 35 ° C is φ = 98%;
  • Preheating of the cable is not required during laying at t≥ -15˚C;
  • The limiting operating temperature of heating the core of the conductor is t = 70 ° C;
  • When an emergency overload occurs, heating of current-carrying conductors to t = 130 ° C is permitted;
  • The maximum value of the heating temperature of the core in the short-circuit mode is t = 250 ° C;
  • Depending on the number of conductor cores, the value of the minimum bend radius of the conductor is normalized: single-core - 7,5D; Stranded - 10D;
  • The work period is 30 years;
  • Manufacturer's warranty is 5 years.

Buy cable АПвБбШп

Our company makes delivery of power conductor APVBbShp in Russia by the gross. The sale is carried out with the availability of cable products or orders are made to the manufacturers. The application for the purchase of goods can be left on our website or sent to the specified email address. After submitting an application for you promptly will be prepared a commercial offer, a convenient way and conditions for the delivery of goods. When certain conditions  you can be offered discounts.

Power cable АПвБбШп, as well as АПвБШп (GOST-R 53769-2010) is designed for laying electrical networks  in channels, mines, on the street or indoors, where strong tensile loads do not act on it. Serves for the distribution and transmission of electricity at fixed facilities with a voltage of up to 1kV at a frequency of 50Hz. Cable armored APVBbShp-1 kV fully complies with all GOST requirements for both areas with cold and temperate climate, and for wet and dry tropical zones. The estimated interval of threshold use temperatures is in the range from -45 to +50 ° C.

The protective insulation of the APVBbShp wire is made of the SPE material, and the current-carrying function is made of cores made of aluminum. In the decoding of the cable, this is indicated by the letter A in the name. Litera Pv reports that the layer of internal insulation is made of EIT. Бб means a double armored shell. The symbols Шп denote that the outer sheath of the wire is made of a hose of polyvinylchloride material.

The cable can be either solid or stranded. In multi-stranded varieties, this or that vein has its own color different from the others, for example the insulation of the conductive element of the phase is zero-light blue, and the standard color of the earth conductor is yellow with a green line. Often, the marking is carried out with a continuous or with an additional longitudinal strip, or even with the help of digital symbols.

The most popular cross-section of APVBbShp cable is available in our warehouse in Moscow. You can easily buy cross-sections: 4х240; 4х185; 4х150; 4х120; 4х95 mm2. To clarify the availability of the stock, the price of the required components, as well as the cost of delivery, customers are advised to make a call to the number specified in the "Contacts" section.

Name Unit. Price *
АПвБбШп 1х50 (ож) -1 m 56,74
АПвБбШп 1х70-1 m 69,82
АПвБбШп 1х95-1 m 86,39
АПвБбШп 1х120-1 m 103,47
АПвБбШп 1х150-1 m 127,95
АПвБбШп 1х185-1 m 153,38
АПвБбШп 1х240-1 m 189,87
АПвБбШп 1х630-1 m 372,67
АПвБбШп 3х6 (ож) -1 m 49,16
АПвБбШп 3х10 (ож) -1 m 58,69
АПвБбШп 3х16 (ож) -1 m 65,19
АПвБбШп 4х120-1 m 323,91
АПвБбШп 4х150-1 m 390,1
АПвБбШп 4х16 (ож) -0,66 m 77,98
АПвБбШп 4х16 (ож) -1 m 83,83
АПвБбШп 4х185-1 m 473,8
АПвБбШп 4х240-1 m 594,59
АПвБбШп 4х300-1 m 803,00
АПвБбШп 4х400-1 m 1007,76
АПвБбШп 4х25 (ож) -1 m 92,11
АПвБбШп 4х25 (ож) -0,66 m 93,78
АПвБбШп 4х35 (ож) -1 m 119,45
АПвБбШп 4х35 (ож) -0,66 m 119,25
АПвБбШп 4х50 (ож) -1 m 153,5
АПвБбШп 4х50 (ож) -0,66 m 153,82
АПвБбШп 4х70-1 m 202,71
АПвБбШп 4х95-1 m 254,23
АПвБбШп 5х120-1 m 432,8
АПвБбШп 5х150-1 m 525,43
АПвБбШп 5х16 (ож) -1 m 97,7
АПвБбШп 5х185-1 m 606,42
АПвБбШп 5х240-1 m 761,24
АПвБбШп 5х25 (ож) -1 m 119,8
АПвБбШп 5х35 (ож) -1 m 149,86
АПвБбШп 5х50 (ож) -1 m 194,28
АПвБбШп 5х70-1 m 286,23
АПвБбШп 5х95-1 m 368,92

* in rubles for 1 meter without VAT

Popular:

Insulation of the core in the wire SIP is made of thermoplastic light-stabilized cross-linked pvc ...

The VBBC cable includes copper wires, single-stranded or multiwire, with sectoral or round section, second or first class in accordance with GOST 22483. Insulation is made of PVC ...

Marking of wires in numbers or color. Filling from paper strips and belt impregnated paper insulationimpregnated with a viscous insulating impregnating compound ...

SIP-self-supporting insulated wire, is designed to transmit current in overhead power lines and branches to inputs in residential buildings and various structures ...

Index "NG-LS" means that the conductor does not spread fire and is with reduced gas and smoke evolution. The cable sheath and its insulation is made of fireproof pvc that does not spread fire ...

For open mounting on routes with different levels in electronic circuits of AC voltage up to 660 volts or direct current  up to 1000 volts, in explosive-dangerous rooms and technical installations and in premises with chemically-controlled media ...

It is used for laying in the air in the presence of danger of mechanical damage or subjected to significant tensile forces ...

You can always find the wire SIP of various models in our online store. All products presented in our voluminous catalog are products of well-known Russian and world cable manufacturers. The presence of mandatory certificates and excellent technical characteristics make them extremely popular among consumers. Our electrical products serve for a long time, safely and without any serious problems.

Buying wire SIP from us, you can surely count on:

  • convenience of placing an order;
  • favorable terms of cooperation;
  • prompt delivery of the order, regardless of its volume;
  • transportation of cable products even to the most remote regions of Russia;
  • personal approach and help in the selection of goods.

Our company really values ​​its reputation. We are extremely responsible for fulfilling all obligations to our customers, therefore, each and every one of our customers can be confident that cooperation will be organized on a professional basis.

Cable SIP specifications, price

Performance indicators and convenient use of SIP wires are better than bare analogs. With their help solve the problem of air transmission of electricity. Paving such electrical cables will be significantly cheaper. Absolutely no chance of closure between phases. But the insulation material must have a suitable condition (without damage).

Specifications  CIP Cable

  • Ambient temperature - from -60С to + 50С
  • Rated voltage - 0,6 / 1kV
  • The maximum continuous operating temperature is 90С
  • The lowest temperature of the gasket without heating the cable is -20С
  • The limiting temperature of the conductors in the emergency mode (overload) is 130С
  • Minimum bending radius for laying - 10 diameters
  • The highest temperature of the cores at short-circuiting is -25 ° C
  • Total service life - 40 years

Laying SIP does not need the services of highly professional fitters. Laying this electrical cable does not require insulators or special support structures, since it is allowed to lay the SIP along the wall of the building. The main thing is the installation and fixing of the electric cable according to the SNiP standard. CIP cables have a long service life of 40 years.

APVBbShp - obsolete marking of power armored cable  with aluminum conductors in insulation and a jacket made of cross-linked polyethylene, since 2011, in connection with the entry into force of the new GOST-R 53769-2010, the marking has changed to APVBshp., the design and specifications have not changed.

The price of the cable armored APVBbShp varies depending on the cost of aluminum and plastic used in its manufacture, the current price of the storage cable APVBbShp is indicated in the section price list, discounts are given from the total amount of the order, the final price for the APVBPSH cable please contact the manager.

Buy APVBbShV cable can be physical and legal persons by cash or by bank transfer, shipment of the storage cable APVBbShp is made within one day after payment, the terms for custom positions are specified by the manager.

Explanation of the marking APVBbShp (g):

A - aluminum conductors.
  Pv - XLPE insulation.
  Бб - armor from steel zinced ribbons.
  Шп - sheath of cross-linked polyethylene.
  (d) - meets the requirements of MKS Mosenergo.

Cable specifications APVBbShv:

The climatic design of the cable armored APVBbShp - UHL, the first and second categories of placement in accordance with GOST 15150-69.
The operating temperature of APVBbShp cable is from -60 to +50 degrees Celsius.
Installation of power cable of aluminum APVBbShp  without preheating is carried out at a temperature not lower than -20 degrees.
The service life of the cable armored aluminum APVBbShp not less than 30 years from the date of manufacture.
Cable АПвБбШп (г) - corresponds to the requirements of МКС "Mosenergo".

Cable construction АПВБбШп:

1) The core - aluminum, first or second class in accordance with GOST 22483-77.
  2) Insulation - made of cross-linked polyethylene.
  3) The inner sheath is made of polyethylene.
  4) Armor - of two steel zinc-coated ribbons.
  5) Protective hose - made of cross-linked polyethylene.

Application of the cable APVBBShp:

Power armored cable APVBbShp are designed for laying in the ground (trenches) regardless of the corrosive activity of soils and groundwater.
It is allowed to use them for laying through non-navigable rivers and reservoirs provided they are buried in the ground.

  A - Aluminum conductor
Pv - Insulation of cores made of cross-linked polyethylene
B - Armor of two steel ribbons
b - Without a pillow, which is the inside of the protective cover, placed under the armor in order to protect the underlying element from corrosion and mechanical damage with ribbons or armor wires
Шп - Protective cover in the form of an extruded hose made of polyethylene

Elements of cable construction APVBBShp:

1. Conductor:
- material - aluminum:
- Number of cores: 3 + 1, 4, 5.

cross-section of conductors:

from 4 to 240 mm2 (single-wire core - coolant),
from 25 to 240 mm2 (stranded wire);

2. Insulation of cross-linked polyethylene ( color marking  veins);
3. The core;
4. Fastening winding (for cables with cross section 50mm2 and above);
5. Belt insulation made of polyethylene or PVC plastic;
6. Armor of two steel zinc-coated ribbons;
7. Protective hose made of polyethylene.

Application area of ​​APVBbShp cable:

Power cables are designed for transmission and distribution electric power  in fixed installations for a rated alternating voltage of 1.0 kV at a frequency of 50 Hz.
Cables are manufactured for operation in areas with a temperate and cold climate. Cables are designed for operation on land, rivers and lakes at altitudes up to 4300 m above sea level. Cables are used for laying:
- in the ground (trenches) with low, medium or high corrosive activity, with or without stray currents, and if during the operation the cables are not subjected to significant tensile forces;
- in soils with high humidity;
- in water.

Cables are designed for vertical, inclined and horizontal routes. Permissible heating of conductors in emergency mode should not exceed + 130 ° С and the duration of operation in emergency mode should not exceed 6 hours per day.

Service life is 30 years.

Support the project - share the link, thank you!
Read also
The device and principle of operation of the LED lamp The device and principle of operation of the LED lamp Soft starters: the right choice Soft starters: the right choice Transforming an electronic transformer into a more powerful one Transforming an electronic transformer into a more powerful one